article = {SCR-2019-5-112} title = {A Case of Two Consecutive Peri-Implant Fractures After Treatment of an Incomplete Stress Fracture of the Femoral Neck with a Sliding Hip Screw Device in a Young Adult} journal = {Surgical Case Reports} year = {2019} issn = {2613-5965} doi = {http://dx.doi.org/10.31487/j.SCR.2019.05.12} url = {https://www.sciencerepository.org/a-case-of-two-consecutive-peri-implant-fractures-after-treatment-of-an-incomplete-stress-fracture-of-the-femoral-neck_SCR-2019-5-112 author = {Abhishek Ganta,Sanjit R Konda,Utkarsh Anil,} keywords = {Peri-Implant Fractures, Stress Fracture, Femoral Neck} abstract ={We present an atypical presentation of a non-displaced femoral neck fracture in a young adult after a fall from standing sustained 4 days prior to presentation. Patient underwent surgical fixation with a sliding hip screw, the postoperative course of which was complicated by an atraumatic peri-implant greater trochanteric fracture, requiring surgery for open reduction and internal fixation. The course was further complicated by another atraumatic peri-implant femoral neck fracture after which, the patient was definitely treated with a total hip arthroplasty.}